Spoolset › Charts › Schedule 80 pipe dimensions

Schedule 80 pipe dimensions

Twelve nominal sizes, with the bore and the volume derived from the two published figures rather than looked up separately.

Every figure on this page is produced by the same code as the Spoolset app — not re-typed from it.

Schedule 80, ASME B36.10M

SizeOutside dia.WallBore
1/2"0.840″0.147″0.546″
3/4"1.050″0.154″0.742″
1"1.315″0.179″0.957″
1-1/4"1.660″0.191″1.278″
1-1/2"1.900″0.200″1.500″
2"2.375″0.218″1.939″
2-1/2"2.875″0.276″2.323″
3"3.500″0.300″2.900″
4"4.500″0.337″3.826″
5"5.563″0.375″4.813″
6"6.625″0.432″5.761″
8"8.625″0.500″7.625″

Schedule 80 carries the same outside diameter as schedule 40 and a heavier wall, so every gain in pressure rating is paid for in bore. On 2″ pipe the bore drops from 2.067″ to 1.939″, which is about 12% of the flow area gone.

Bore area and volume

SizeBore areaUS gal/ftLitres/ft
1/2"0.234 in²0.01220.0460
3/4"0.432 in²0.02250.0850
1"0.719 in²0.03740.1414
1-1/4"1.283 in²0.06660.2523
1-1/2"1.767 in²0.09180.3475
2"2.953 in²0.15340.5807
2-1/2"4.238 in²0.22020.8334
3"6.605 in²0.34311.2989
4"11.497 in²0.59722.2608
5"18.194 in²0.94513.5777
6"26.067 in²1.35415.1259
8"45.664 in²2.37218.9795

These three columns are arithmetic, not lookups: bore is OD − 2 × wall, area is π × (bore/2)², and a US gallon is 231 in³, so gallons per foot is area × 12 / 231. Nothing here can disagree with the table above it.

Why the outside diameter does not change with schedule

Nominal Pipe Size is a name, not a measurement — 2″ pipe has an outside diameter of 2.375″ in every schedule. Only the wall thickness changes, inward, so the bore shrinks while the fitting that goes over it stays the same. That is what makes schedules interchangeable at a joint and why a take-out is a function of NPS alone.

Below about 12″ the nominal size bears no useful relation to any dimension of the pipe. At and above 14″ it becomes the outside diameter exactly — which is outside the range of this table.

Related charts

Schedule 40 dimensions

Outside diameter, wall and bore for twelve sizes.

Pipe volume per foot

Gallons and litres per foot, derived from the bore.

Elbow take-out chart

ASME B16.9 long-radius centre-to-face, ½″ through 8″.

4" pipe data

Outside diameter, wall, bore, volume and the B16.9 elbow take-outs.

Do this on the job, not at a desk

Spoolset runs these calculations on an iPhone and draws the shape to scale as you type, so a mistyped number shows up as a wrong picture. It cites the source of every table it uses. Simple offsets and grade are free; rolling offsets and the take-out tables are a one-time purchase.

Download on the App Store