Spoolset › Charts › Drain pipe slope by pipe size
Drain pipe slope by pipe size
The minimum slope is not one number — it drops in three steps as the pipe gets bigger. Here are the three, and the fall each one produces.
Every figure on this page is produced by the same code as the Spoolset app — not re-typed from it.
IPC Table 704.1 — minimum slope
| Pipe size | Minimum slope | Percent | Fall per 10′ |
|---|---|---|---|
| 2½″ or less | ¼″ per foot | 2.083% | 2-1/2" |
| 3″ to 6″ | ⅛″ per foot | 1.042% | 1-1/4" |
| 8″ or larger | 1/16″ per foot | 0.521% | 5/8" |
Larger pipe needs less slope because it carries the same flow at a shallower depth, so the velocity that keeps solids moving is reached with less fall. That is the whole reason the table steps down rather than up.
This is the model code, not your jurisdiction. The International Plumbing Code is adopted with amendments, and some authorities require ¼″ per foot on sizes the IPC allows at ⅛″. The UPC and local plumbing codes differ again. Check what has actually been adopted where the work is — this table tells you what to look for, not what you are allowed to do. Sources: ICC and UpCodes, in agreement.
Fall over a run, per band
| Run | ¼″/ft (≤2½″) | ⅛″/ft (3–6″) | 1/16″/ft (≥8″) |
|---|---|---|---|
| 10′ | 2-1/2" | 1-1/4" | 5/8" |
| 20′ | 5" | 2-1/2" | 1-1/4" |
| 25′ | 6-1/4" | 3-1/8" | 1-9/16" |
| 30′ | 7-1/2" | 3-3/4" | 1-7/8" |
| 40′ | 10" | 5" | 2-1/2" |
| 50′ | 12-1/2" | 6-1/4" | 3-1/8" |
| 60′ | 15" | 7-1/2" | 3-3/4" |
| 75′ | 18-3/4" | 9-3/8" | 4-11/16" |
| 100′ | 2' 1" | 12-1/2" | 6-1/4" |
| 150′ | 3' 1-1/2" | 18-3/4" | 9-3/8" |
Read the 100′ row as the argument for the table: a 100 foot run falls 2' 1" in small pipe and 6-1/4" in 8″. In a basement with a fixed ceiling, that difference decides whether the run is possible at all.
Where the pipe size comes from
The bands are nominal pipe sizes, and the bore that goes with each one is on its own page — 2″, 3″, 4″, 6″ and 8″ are the ones the table turns on. Note that 2½″ is the last size in the top band and 8″ is the first in the bottom one, so both boundaries fall between listed sizes rather than on them.
Related charts
¼″ per foot slope
Fall over any run at the standard sanitary grade.
⅛″ per foot slope
Fall over any run at the large-pipe grade.
Percent ↔ inches per foot
The conversion both ways, for drawings that quote a percentage.
Pipe volume per foot
Gallons and litres per foot, derived from the bore.
Do this on the job, not at a desk
Spoolset runs these calculations on an iPhone and draws the shape to scale as you type, so a mistyped number shows up as a wrong picture. It cites the source of every table it uses. Simple offsets and grade are free; rolling offsets and the take-out tables are a one-time purchase.