Spoolset › Charts › Percent ↔ inches per foot
Percent ↔ inches per foot
Drawings quote a percentage. Tapes read in sixteenths. This is the conversion, both ways.
Every figure on this page is produced by the same code as the Spoolset app — not re-typed from it.
Percent → inches per foot
| Percent | Inches per foot | Ratio | mm/m |
|---|---|---|---|
| 0.5% | 1/16" | 1 in 200.0 | 5.0 |
| 1% | 1/8" | 1 in 100.0 | 10.0 |
| 1.0417% ← ⅛″/ft | 1/8" | 1 in 96.0 | 10.4 |
| 1.5% | 3/16" | 1 in 66.7 | 15.0 |
| 2% | 1/4" | 1 in 50.0 | 20.0 |
| 2.0833% ← ¼″/ft | 1/4" | 1 in 48.0 | 20.8 |
| 2.5% | 5/16" | 1 in 40.0 | 25.0 |
| 3% | 3/8" | 1 in 33.3 | 30.0 |
| 4% | 1/2" | 1 in 25.0 | 40.0 |
| 5% | 5/8" | 1 in 20.0 | 50.0 |
| 6% | 3/4" | 1 in 16.7 | 60.0 |
| 8% | 15/16" | 1 in 12.5 | 80.0 |
| 10% | 1-3/16" | 1 in 10.0 | 100.0 |
Inches per foot → percent
| Inches per foot | Percent | Ratio | mm/m |
|---|---|---|---|
| 1/16" | 0.5208% | 1 in 192.0 | 5.2 |
| 1/8" | 1.0417% | 1 in 96.0 | 10.4 |
| 3/16" | 1.5625% | 1 in 64.0 | 15.6 |
| 1/4" | 2.0833% | 1 in 48.0 | 20.8 |
| 3/8" | 3.1250% | 1 in 32.0 | 31.2 |
| 1/2" | 4.1667% | 1 in 24.0 | 41.7 |
| 5/8" | 5.2083% | 1 in 19.2 | 52.1 |
| 3/4" | 6.2500% | 1 in 16.0 | 62.5 |
| 1" | 8.3333% | 1 in 12.0 | 83.3 |
The conversion in one line either way: percent = inches per foot × 100 / 12, and
inches per foot = percent × 12 / 100. The only two values a plumber needs to
recognise on sight are 2.08% = ¼″ per foot and
1.04% = ⅛″ per foot.
Why a drawing says one and a tape says the other
A percentage is dimensionless, so a civil drawing can use it for a sewer, a road and a roof without changing units. Inches per foot is what a spirit level and a tape actually produce on a short run — at 2.08% over a 4′ stick the fall is 1", which is a mark you can see. Both describe the same line; the argument is only ever about which one is easier to check.
Related charts
¼″ per foot slope
Fall over any run at the standard sanitary grade.
⅛″ per foot slope
Fall over any run at the large-pipe grade.
Drain slope by pipe size
IPC Table 704.1 minimum slopes, with the fall they produce.
Pipe volume per foot
Gallons and litres per foot, derived from the bore.
Do this on the job, not at a desk
Spoolset runs these calculations on an iPhone and draws the shape to scale as you type, so a mistyped number shows up as a wrong picture. It cites the source of every table it uses. Simple offsets and grade are free; rolling offsets and the take-out tables are a one-time purchase.